Zoeken
Zoeken kan via de modus 'eenvoudig zoeken' (één veld) of uitgebreid via 'geavanceerd zoeken' (meerdere velden). Zo kan je bv. zoeken op een combinatie van een auteursnaam (auteur), een jaartal (jaar) en een documenttype.
Boekenmand
Nuttige resultaten kan je aanvinken en toevoegen aan een mandje. De inhoud hiervan kan je exporteren of afdrukken (naar bv. PDF).
RSS
Op de hoogte blijven van nieuw toegevoegde publicaties binnen uw interessegebied? Dit kan door een RSS-feed (?) te maken van jouw zoekopdracht.
nieuwe zoekopdracht
Measurement of freely dissolved PAH concentrations in sediment beds using passive sampling with low-density polyethylene strips
Fernandez, L.A.; MacFarlane, J.K.; Tcaciuc, A.P.; Gschwend, P.M. (2009). Measurement of freely dissolved PAH concentrations in sediment beds using passive sampling with low-density polyethylene strips. Environ. Sci. Technol. 43(5): 1430-1436. dx.doi.org/10.1021/es802288w
In: Environmental Science and Technology. American Chemical Society: Easton. ISSN 0013-936X; e-ISSN 1520-5851, meer
| |
| Auteurs | | Top |
- Fernandez, L.A.
- MacFarlane, J.K.
- Tcaciuc, A.P.
- Gschwend, P.M.
|
|
|
| Abstract |
To assess hydrophobic organic chemical (HOC) contamination in sediments, a method was developed using polyethylene (PE) passive samplers inserted directly in the intact sediment beds to measure freely dissolved HOC concentrations. Performance reference compounds (PRCs: d10-phenanthrene, d10-pyrene, and d12-chrysene), impregnated into the PE before use, allowed porewater concentrations to be deduced after exposure times much shorter than would be required for sampler equilibration (days instead of months). Three diverse sediments were used in the laboratory, and PE-deduced porewater concentrations of six native PAHs (phenanthrene, anthracene, fluoranthene, pyrene, benz(a)anthracene, and chrysene) matched results from air-bridge testing and from direct porewater extractions after correcting for colloid effects. PE strips, deployed from a boat in Boston Harbor, yielded concentrations that were like those measured in porewaters from a sediment core collected nearby. Notably, equilibrium partitioning (EqP) estimates were always much higher (up to 100×) than those measured using the other methods, suggesting the large inaccuracy of that approach. Hence, PE passive sampling appears to greatly improve the accuracy of assessing the hazards posed by compounds like PAHs in sediment beds. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.