Performance of laboratories in speciation analysis in seafood - Case of methylmercury and inorganic arsenic
Baer, I.; Baxter, M.; Devesa, V.; Velez, D.; Raber, G.; Rubio, R.; Llorente-Mirandes, T.; Sloth, J.; Robouch, P.; de la Calle, B. (2011). Performance of laboratories in speciation analysis in seafood - Case of methylmercury and inorganic arsenic. Food Control 22(12): 1928-1934. https://dx.doi.org/10.1016/j.foodcont.2011.05.005
In: Food Control. Butterworth Scientific/Elsevier: London. ISSN 0956-7135; e-ISSN 1873-7129
| |
| Author keywords |
Interlaboratory comparison; Methylmercury; Inorganic arsenic;Speciation; Seafood; IMEP |
| Auteurs | | Top |
- Baer, I.
- Baxter, M.
- Devesa, V.
- Velez, D.
|
- Raber, G.
- Rubio, R.
- Llorente-Mirandes, T.
|
- Sloth, J.
- Robouch, P.
- de la Calle, B.
|
| Abstract |
The international measurement evaluation program (IMEP) has together with the European Reference Laboratory for Heavy Metals in Feed and Food (EU-RL-HM) carried out two interlaboratory comparisons (ILC) in 2010 on the measurement of trace metals, as well as methylmercury and inorganic arsenic in seafood. In IMEP-109 only EU National Reference Laboratories (NRL) took part, while IMEP-30 was open to all laboratories. In this article only methylmercury and inorganic arsenic analysis will be discussed, as these appear generally to be more problematic measurands. They are also particularly interesting to legislators, as no maximum limits have been set yet for them in European legislation. The aim of the two ILCs was to produce more information to help tackling this issue. The results of the two exercises were pooled together, evaluated, and compared with former ILC projects for methylmercury and inorganic arsenic analysis. Results for inorganic arsenic were spread, but not method dependant. The measurand seems to be difficult to analyse in this matrix and possible method issues were identified. Methylmercury results were satisfactory, but not many laboratories perform this type of analysis because it is generally believed that specific instrumentation is needed. As an answer to this presumption, alternatives are suggested. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.