Zoeken
Zoeken kan via de modus 'eenvoudig zoeken' (één veld) of uitgebreid via 'geavanceerd zoeken' (meerdere velden). Zo kan je bv. zoeken op een combinatie van een auteursnaam (auteur), een jaartal (jaar) en een documenttype.
Boekenmand
Nuttige resultaten kan je aanvinken en toevoegen aan een mandje. De inhoud hiervan kan je exporteren of afdrukken (naar bv. PDF).
RSS
Op de hoogte blijven van nieuw toegevoegde publicaties binnen uw interessegebied? Dit kan door een RSS-feed (?) te maken van jouw zoekopdracht.
nieuwe zoekopdracht
Electrochemical studies of ethoxyquin and its determination in salmon samples by flow injection analysis with an amperometric dual detector
Vandeput, M.; Rodríguez-Gómez, R.; Izere, A.-M.; Zafra-Gomez, A.; De Braekeleer, K.; Delporte, C.; Van Antwerpen, P.; Kauffmann, J.-M. (2018). Electrochemical studies of ethoxyquin and its determination in salmon samples by flow injection analysis with an amperometric dual detector. Electroanalysis 30(7): 1293-1302. https://dx.doi.org/10.1002/elan.201700611
In: Electroanalysis. Wiley-VCH: Weinheim. ISSN 1040-0397; e-ISSN 1521-4109
| |
| Author keywords |
Ethoxyquin; EC-LC-MS; Screen printed electrodes; FIA; Salmon |
| Auteurs | | Top |
- Vandeput, M.
- Rodríguez-Gómez, R.
- Izere, A.-M.
- Zafra-Gomez, A.
|
- De Braekeleer, K.
- Delporte, C.
- Van Antwerpen, P.
- Kauffmann, J.-M.
|
|
| Abstract |
Ethoxyquin (EQ) is an antioxidant widely used in the food industry. Some concerns for human health have been reported since its utilization in animal feed may lead to residues in human food such as salmon samples. This work aimed to investigate the electrochemical behavior of EQ and its major oxidation products namely a dimer of EQ (EQDM) and ethoxyquin quinone imine (EQI) by cyclic voltammetry (CV) at a carbon screen printed electrode (cSPE). The stability of these products and their reactivity against glutathione (GSH) were also studied. Oxidized products and thiol adducts were identified by a microelectrolysis of an EQ solution onto a cSPE in the absence and in the presence of GSH. The products were analyzed off-line, by liquid chromatography coupled to a mass spectrometer (LC-MS). One of the generated product (EQI) was shown to be highly reactive towards GSH. Based on the redox pattern of EQ, a flow injection analysis with a dual cSPE was developed in order to detect in a rapid manner EQ in salmon samples. Since matrix effects were observed, matrix-matched calibration curves with spiked samples were built. A linear response was obtained between 20-100M and a limit of detection (LOD) of 7.5M (8.2mg/kg of salmon). Trueness was assessed with recovery assays at three levels of concentration. The recovery was close to 100%. Precision was determined as RSD (%) with values lower than 6% in all cases. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.