Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Validation of a dynamic ammonium extraction technique for the determination of 15N at enriched abundances
Diaconu, C.; Brion, N.; Elskens, M.; Baeyens, W.F.J. (2005). Validation of a dynamic ammonium extraction technique for the determination of 15N at enriched abundances. Anal. Chim. Acta 554(1-2): 113-122
In: Analytica Chimica Acta. Elsevier: New York; Amsterdam. ISSN 0003-2670; e-ISSN 1873-4324, meer
| |
Auteurs | | Top |
- Diaconu, C.
- Brion, N., meer
- Elskens, M., meer
- Baeyens, W.F.J., meer
|
|
|
Abstract |
A diffusion method for extracting ammonium from marine, estuarine and fresh waters for 15N/14N isotopic ratio determinations at enriched level was developed and validated. The method is based on the conversion of NH4+ to NH3 gas under alkaline conditions, diffusion of NH3 out of the solution to the headspace, NH3 trapping on an acidified GF/D glass fiber filter, and subsequent 15N/14N isotope ratio determination with mass spectrometry. The diffusion period necessary to extract sufficient N in order to accurately measure the atom% 15N was reduced to less than 15 h by bubbling the sample with a carrier gas (Air) at room temperature. The technique uses 250 mL sample volume and enables accurate atom% 15N measurements in NH4+ pools as small as 1.25 μM. A standard operating procedure for ammonium extraction is given involving method performance criteria, such as accuracy, precision, detection limit, quantification limit and robustness. The efficiency of the NH4+ extraction ranged from 40 to 100%. The quantification limit of the method was estimated at around 0.26 μmol% N, for an initial 15N abundance of 1%. The within-laboratory reproducibility amounted to 0.03 atom% 15N. It was shown that the recovery rate obtained after extraction of the certified reference material (CRM: IAEA-311) solution falls within the 95% confidence interval of the certified values. By applying the developed method to fortified natural water samples of different conductivities, the atom% 15N determinations were precise and accurate for α = 1–5%. |