Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Field monitoring of ship wave action on environmentally friendly bank protection in a confined waterway
De Roo, S.; Troch, P. (2013). Field monitoring of ship wave action on environmentally friendly bank protection in a confined waterway. J. Waterway Port Coast. Ocean Eng. 139(6): 527-534. dx.doi.org/10.1061/(ASCE)WW.1943-5460.0000202
In: Journal of Waterway, Port, Coastal, and Ocean Engineering. American Society of Civil Engineers (ASCE): New York, N.Y.. ISSN 0733-950X; e-ISSN 1943-5460, meer
| |
Author keywords |
Ship motion; Experimentation; River bank stabilization; Field tests;Wave action; Sediment; Waterways; Belgium; Ship wave action;Experimental design; River bank stabilization; Biotechnical engineering;Field tests; Wave action; Ships; Sediment resuspension; Belgium |
Abstract |
The road toward a sustainable inland waterway network entails the installation of ecologically sound and technically effective bank protection. Heavy shipping traffic complicates the development of environmentally friendly bank protection on confined, nontidal waterways. Because in such conditions ship waves vary with ship design and operation, with topographic boundaries and locally changing hydraulic conditions, ship wave action is poorly understood. Therefore, a stand-alone field monitoring system was designed that accurately measures the impact on and response of environmentally friendly bank protection, consisting of off-bank timber piling and vegetation (reeds). Subsequently, the instrumentation was re-engineered and extended to a mobile version, enhancing the dynamic measurement possibilities. In this paper, the setup of both measurement systems is described, together with a detailed overview of the selected measurement instrumentation and good installation practices. The added value of these field monitoring systems is illustrated with an example of the monitoring system's data output. |