Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Gas chromatography-ion trap tandem mass spectrometry method for the analysis of methoxylated polybrominated diphenyl ethers in fish
Losada, S.; Santos, F.; Covaci, A.; Galceran, M. (2010). Gas chromatography-ion trap tandem mass spectrometry method for the analysis of methoxylated polybrominated diphenyl ethers in fish. J. Chromatogr. 1217(32): 5253-5260. https://dx.doi.org/10.1016/j.chroma.2010.06.023
In: Journal of Chromatography A. Elsevier: Amsterdam. ISSN 0021-9673; e-ISSN 1873-3778, meer
| |
Trefwoorden |
Pisces [WoRMS] Marien/Kust |
Author keywords |
PBDEs; MeO-PBDE; Flame retardants; PLE; GC-EI-MS-MS; Fish; Shellfish |
Auteurs | | Top |
- Losada, S., meer
- Santos, F.
- Covaci, A., meer
- Galceran, M.
|
|
|
Abstract |
Gas chromatography coupled to ion trap tandem mass spectrometry (GC–ITMS-MS) is proposed for the analysis of methoxylated polybrominated diphenyl ethers (MeO-PBDEs) in fish and shellfish. MS–MS operating parameters related to the isolation and fragmentation of the precursor ions were optimized to achieve maximum sensitivity and selectivity. This new method allows the determination of both MeO-PBDEs and PBDEs in a single run. Low limits of detection (0.4–2.5 pg injected) and high precision (RSD < 13%) were achieved. A sample treatment based on a selective pressurized liquid extraction (PLE) using Florisil as fat retainer was applied for the analysis of these compounds in fish samples. Method limits of quantification ranged from 0.11 to 0.95 ng g-1 lipid weight for MeO-PBDEs and between 0.18 and 0.50 ng g-1 lipid weight for PBDEs. In addition, good repeatability of the whole method was achieved (RSD < 15%). The suitability of the method was evaluated by analyzing a certified reference material (SRM 1945, whale blubber) with satisfactory results. The developed method was applied to the simultaneous analysis of MeO-PBDEs and PBDEs in fish and shellfish samples from the Mediterranean Sea. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.