Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Field tests of dielectric sensors in a facility for studying salt tolerance of crops
van Straten, G.; de Vos, A; Vlaming, R.; Oosterbaan, R. (2016). Field tests of dielectric sensors in a facility for studying salt tolerance of crops. International Agricultural Engineering Journal 25(2): 102-113
In: International Agricultural Engineering Journal. Asian Association for Agricultural Engineering: Bangkok. ISSN 0858-2114, meer
| |
Author keywords |
salt tolerance, electrical conductivity, volumetric water content, soil sensor, calibration, salinity, irrigation |
Auteurs | | Top |
- van Straten, G.
- de Vos, A, meer
- Vlaming, R.
- Oosterbaan, R.
|
|
|
Abstract |
Seven salinity levels ranging from 1.7 to 35 dS/m are applied to groups of eight fields each in a field facility for testing the salt tolerance of crops. Each of the 56 test fields is equipped with one or two dielectric sensors for soil volumetric water content (VWC) and bulk electric conductivity (ECb). Several models for calibrating the sensors in the laboratory were tested and parameterized. Overall, the root mean square error was in the range of 0.57-0.59 dS/m in terms of soil bulk EC. The models differed in their robustness against inversion to obtain pore water EC from measured bulk EC. The laboratory calibration formula overestimates the pore water EC at low EC (5 dS/m), and underestimates it at high EC (25 dS/m). In practice, calculated sensor pore water EC‟s in fields with the same salinity treatment differ among each other, showing the limitations of laboratory calibrations. However, in fields where pore water samples are available, a direct proportionality between pore water EC and sensor bulk EC suffices without correction for VWC in this well irrigated case. Moreover there is a good correlation between the low frequent EC time series of suction cup samples and the high frequent sensor readings. When used with care, sensors can give valuable information about the dynamics of soil conditions during crop salinity tolerance tests. |