Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Three-dimensional reconstruction of the tissue-specific multielemental distribution within Ceriodaphnia dubiavia multimodal registration using laser ablation ICP-mass spectrometry and X-ray spectroscopic techniques
Van Malderen, S.J.M.; Laforce, B.; Van Acker, T.; Nys, C.; De Rijcke, M.; de Rycke, R.; De Bruyne, M.; Boone, M.N.; De Schamphelaere, K.; Borovinskaya, O.; De Samber, B.; Vincze, L.; Vanhaecke, F. (2017). Three-dimensional reconstruction of the tissue-specific multielemental distribution within Ceriodaphnia dubiavia multimodal registration using laser ablation ICP-mass spectrometry and X-ray spectroscopic techniques. Anal. Chem. 89(7): 4161-4168. https://dx.doi.org/10.1021/acs.analchem.7b00111
In: Analytical chemistry. American Chemical Society: Washington. ISSN 0003-2700; e-ISSN 1520-6882, meer
| |
Auteurs | | Top |
- Van Malderen, S.J.M., meer
- Laforce, B., meer
- Van Acker, T., meer
- Nys, C., meer
- De Rijcke, M., meer
|
- de Rycke, R., meer
- De Bruyne, M., meer
- Boone, M.N., meer
- De Schamphelaere, K., meer
|
- Borovinskaya, O.
- De Samber, B., meer
- Vincze, L., meer
- Vanhaecke, F., meer
|
Abstract |
In this work, the three-dimensional elemental, distribution profile within the freshwater crustacean Ceriodaphnia dubia was constructed at a spatial resolution down to S mu m via a data, fusion approach employing state-of-the-art laser ablation inductively coupled plasma-time-of-flight mass spectrometry (LAICP-TOFMS) and laboratory-based absorption microcomputed tomography (mu-CT). C. dubia was exposed to elevated Cu, Ni, and Zn concentrations, chemically fixed, dehydrated, stained, and embedded, prior to mu-CT analysis. Subsequently, the sample was cut into 5 pm thin sections that were subjected to LA-ICPTOFMS imaging. Multimodal image registration was performed to spatially align the 2D LA-ICP-TOFMS images relative to the Corresponding slices of the 3D mu-CT reconstruction. Mass channels corresponding to the isotopes of a single element were merged to improve the signal-to-noise ratios within the elemental images. In order to aid the visual interpretation of the data, LA-ICP-TOEMS data wete projected onto the mu-CT voxels representing tissue. Additionally, the image resolution and elemental sensitivity were compared to those obtained with synchrotron radiation based 3D confocal mu-X-ray fluorescence imaging upon a chemically fixed and air-dried C. dubia specimen. |