Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Numerical modelling of a multi-chambered low-reflective caisson
Tagliafierro, B.; Crespo, A.J.C.; González-Cao, J.; Altomare, C.; Sande, J.; Peña, E.; Gomez-Gesteira, M. (2020). Numerical modelling of a multi-chambered low-reflective caisson. Appl. Ocean Res. 103: 102325. https://hdl.handle.net/10.1016/j.apor.2020.102325
In: Applied Ocean Research. CML Publications/Elsevier: Southampton. ISSN 0141-1187; e-ISSN 1879-1549, meer
| |
Author keywords |
Partially perforated wall; Low-reflective caisson; OpenFOAM (R); Reflection coefficient; Multi-chambered caisson; Low front-wall porosity |
Auteurs | | Top |
- Tagliafierro, B.
- Crespo, A.J.C.
- González-Cao, J.
- Altomare, C., meer
|
- Sande, J.
- Peña, E.
- Gomez-Gesteira, M.
|
|
Abstract |
The efficiency of a low-reflective caisson built at the Outer Port of Punta Langosteira (A Coruna, Spain), with a front-wall porosity of approximate to 5%, has been numerically investigated by means of OpenFOAM (R) for different chamber configurations and different sea states. The numerical model is validated with data coming from experimental tests performed on a scaled prototype. First, two different water levels, low and mean tide levels, are analysed. Results show that the caisson is inefficient when the water level inside the chamber is low, and suggest its proper installation taking into account the tidal regime of the area. For mean tide level inside the chamber, the efficiency of the caisson shows to be strongly dependent on the wave period and height. However, it is shown to be more sensitive to the period for low wave heights than for the high ones. Overall, the reflection coefficient ranged from 0.365 (B/L-c = 0.14 s, H = 0.02 m) to 0.660 (B/L-c = 0.26 s, H = 0.02 m). Alternative configurations with one and two chambers are also examined instead of three. Overall, the reflection coefficient is very high ( > 0.95) for the configuration with only one chamber. For the two and three-chambered caissons the mean reflection coefficient is similar ( approximate to 0.5) but the dispersion of the values is much higher for the two-chambered caisson, with values ranging from 0.176 to 0.794. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.