Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
Offshore Hydrogen Production via the PEM Electrolyser Coupled With the Reverse Osmosis System
Asiaban, S.; Bozalakov, D.; Cornelissen, E.; Vandevelde, L. (2025). Offshore Hydrogen Production via the PEM Electrolyser Coupled With the Reverse Osmosis System. IEEE Access 13: 161685-161708. https://dx.doi.org/10.1109/ACCESS.2025.3608297
In: IEEE Access. IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC: Piscataway. ISSN 2169-3536; e-ISSN 2169-3536, meer
| |
| Author keywords |
Hydrogen;Production;Electrochemical processes;Desalination;Costs;Pipelines;Wind turbines;Topology;Reverse osmosis;Wind farms;PEM electrolyser;offshore hydrogen;seawater;performance;energy;simulation;design;model;temperature;observer;cells;power |
| Auteurs | | Top |
- Asiaban, S.
- Bozalakov, D., meer
- Cornelissen, E., meer
- Vandevelde, L., meer
|
|
|
| Abstract |
Offshore production of hydrogen using seawater reverse osmosis (SWRO) and proton exchange membrane (PEM) technologies offers a promising pathway for green hydrogen generation from renewable energy sources (RESs). Realising this potential requires the integration of the SWRO unit and PEM electrolyser into a single system, with precise modelling to address the variability of RESs. Nevertheless, there are limited studies in the literature that examine a coupled SWRO-PEM electrolyser model. Therefore, in this article, an integrated SWRO-PEM electrolyser model is developed, detailing the modelling steps for each component. The models are subsequently validated against experimental data and upscaled to reflect a realistic scenario. Finally, a straightforward control method for the SWRO unit based on the electrolyser operation is suggested. The PEM electrolyser model showed an average relative error of 0.66% in static operation and 3.93% in dynamic operation. Meanwhile, the SWRO unit demonstrated an average relative error of 3.64% for water quantity and 1.48% for water quality compared to experimental results at low total dissolved solids (TDS) values, and 2.74% and 0.13% for water quantity and quality, respectively, at seawater TDS levels. Also, the control method estimated the water demand of the electrolyser with an average error of 1.20%. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.