Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
[ meld een fout in dit record ] | mandje (1): toevoegen | toon |
one publication added to basket [353007] | |
Physiology of repeated mixed gas 100-m wreck dives using a closed-circuit rebreather: a field bubble study Balestra, C.; Guerrero, F.; Theunissen, S.; Germonpré, P.; Lafère, P. (2022). Physiology of repeated mixed gas 100-m wreck dives using a closed-circuit rebreather: a field bubble study. Europ. J. Appl. Physiol. 122(2): 515-522. https://dx.doi.org/10.1007/s00421-021-04856-5
In: European Journal of Applied Physiology. Springer: Berlin. ISSN 1439-6319; e-ISSN 1439-6327, meer
|
Beschikbaar in | Auteurs |
Trefwoord |
|
Author keywords |
|
Auteurs | Top | |
Abstract |
PurposeData regarding decompression stress after deep closed-circuit rebreather (CCR) dives are scarce. This study aimed to monitor technical divers during a wreck diving expedition and provide an insight in venous gas emboli (VGE) dynamics. MethodsDiving practices of ten technical divers were observed. They performed a series of three consecutive daily dives around 100 m. VGE counts were measured 30 and 60 min after surfacing by both cardiac echography and subclavian Doppler graded according to categorical scores (Eftedal–Brubakk and Spencer scale, respectively) that were converted to simplified bubble grading system (BGS) for the purpose of analysis. Total body weight and fluids shift using bioimpedancemetry were also collected pre- and post-dive. ResultsDepth-time profiles of the 30 recorded man-dives were 97.3 ± 26.4 msw [range: 54–136] with a runtime of 160 ± 65 min [range: 59–270]. No clinical decompression sickness (DCS) was detected. The echographic frame-based bubble count par cardiac cycle was 14 ± 13 at 30 min and 13 ± 13 at 60 min. There is no statistical difference neither between dives, nor between time of measurements (P = 0.07). However, regardless of the level of conservatism used, a high incidence of high-grade VGE was detected. Doppler recordings with the O’dive were highly correlated with echographic recordings (Spearman r of 0.81, P = 0.008). ConclusionAlthough preliminary, the present observation related to real CCR deep dives questions the precedence of decompression algorithm over individual risk factors and pleads for an individual approach of decompression. |