Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
one publication added to basket [353142] |
Analytical model for availability assessment of large-scale offshore wind farms including their collector system
Abeynayake, G.; Van Acker, T.; Van Hertem, D.; Liang, J. (2021). Analytical model for availability assessment of large-scale offshore wind farms including their collector system. IEEE Trans. Sustain. Energy 12(4): 1974-1983. https://dx.doi.org/10.1109/TSTE.2021.3075182
In: IEEE Transactions on Sustainable Energy. IEEE: Piscataway, N.J.. ISSN 1949-3029; e-ISSN 1949-3037, meer
| |
Trefwoord |
|
Author keywords |
Wind turbines; Wind farms; Markov processes; Wind speed; Distributed power generation; Offshore installations; Power system reliability; Multi-state Markov model; offshore wind; radial systems; availability; reliability; universal generating function |
Auteurs | | Top |
- Abeynayake, G.
- Van Acker, T., meer
- Van Hertem, D., meer
- Liang, J.
|
|
|
Abstract |
With the increase of offshore wind farm size, the use of classical analytical reliability methods becomes computationally intractable. This paper proposes a holistic approach combining multi-state Markov processes and the universal generating function for the availability assessment of radial large-scale offshore wind farms. The proposed model combines multi-state wind turbine output, wind turbine reliability, and inter-array cable reliability models to assess the wind farm output at the point of common coupling. A strategy is developed to split the network into its feeders while still accounting for the wind turbine output dependence, significantly reducing the computational burden. Although the failure rates of inter-array cables are low, their inclusion is pertinent given high repair times and impact on wind farm output given the radial topology of the collection system. A case study on the Anholt wind farm indicates the necessity of accounting for the collection system, showing a significant reduction of 12 % in generation ratio availability for a generation ratio criterion of 95 %. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.