Over het archief
Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
one publication added to basket [392804] |
Optimisation of the depth range of UIV on cohesive sediment (fluid mud) flows
In: Discover Applied Sciences. Springer Nature Switzerland AG. e-ISSN 3004-9261, meer
| |
Trefwoorden |
Hydraulics and sediment > Sediment > Cohesive sediment Hydraulics and sediment > Sediment > Nautical bottom Mud Physical modelling
|
Author keywords |
Depth range; Ultrasound Image Velocimetry (UIV); Echo-PIV |
Project | Top | Auteurs |
- Ontwikkeling van onderzoeksinfrastructuur ter ondersteuning van nautisch onderzoek, meer
|
Abstract |
Ultrasound Image Velocimetry (UIV) is a technique that enables the monitoring of flows in natural high-density cohesive sediments, also known as fluid mud. Using conventional medical ultrasound imaging equipment, the depth range of UIV in mud is however too limited. This manuscript discusses how this depth range can be improved based on the results of experimental UIV measurements in fluid mud. The results show that the depth range limitation is determined by the pixel brightness of the generated speckle pattern images. Since pixel brightness is a measure of the intensity of the backscattered signals, it degrades with increasing depth due to the attenuation of the ultrasound radiation by the mud. The rate at which ultrasound is attenuated by fluid mud is constant and is governed by the density of the mud and the applied ultrasound frequency. A greater depth range can thus be achieved by reducing attenuation and increasing the intensity of the emitted ultrasound. The former was confirmed by the results of experiments with variable mud density and ultrasound frequency. Flexibility of both parameters is however restricted, allowing only a limited increase in depth range. Another experiment confirmed an additional increase in depth range when a higher ultrasound intensity is applied. Patient safety measures of medical ultrasound imaging equipment, however restrict the intensity of the emitted ultrasound. To increase the depth range even further, potential solutions are therefore suggested, such as the use of high-power non-medical ultrasound imaging equipment or a novel procedure for processing the acquired acoustic data. |
IMIS is ontwikkeld en wordt gehost door het VLIZ.