Het OWA, het open archief van het Waterbouwkundig Laboratorium heeft tot doel alle vrij toegankelijke onderzoeksresultaten van dit instituut in digitale vorm aan te bieden. Op die manier wil het de zichtbaarheid, verspreiding en gebruik van deze onderzoeksresultaten, alsook de wetenschappelijke communicatie maximaal bevorderen.
Dit archief wordt uitgebouwd en beheerd volgens de principes van de Open Access Movement, en het daaruit ontstane Open Archives Initiative.
Basisinformatie over ‘Open Access to scholarly information'.
one publication added to basket [65813] |
Determination of trace levels of dissolved vanadium in seawater by use of synthetic complexing agents and inductively coupled plasma atomic emission spectroscopy
Abbasse, G.; Ouddane, B.; Fischer, J.-C. (2002). Determination of trace levels of dissolved vanadium in seawater by use of synthetic complexing agents and inductively coupled plasma atomic emission spectroscopy. Anal. Bioanal. Chem. 374(5): 873-878
In: Analytical and Bioanalytical Chemistry. Springer: Heidelberg. ISSN 1618-2642; e-ISSN 1618-2650, meer
| |
Auteurs | | Top |
- Abbasse, G.
- Ouddane, B., meer
- Fischer, J.-C., meer
|
|
|
Abstract |
In the determination of traces of dissolved vanadium in complex matrices such as seawater, separation and enrichment from the matrix is of special importance. A wide variety of methods has been proposed for preconcentration, depending to the nature of samples and the methods to be used for measurement. Among these methods separation techniques based on sorption on to chelating resins seem convenient, rapid, and capable of achieving a high concentration factor. The methods proposed in this paper are based on the transformation of all dissolved vanadium species in seawater into organic complexes by use of synthetic complexing agents such as dithizone, luminol, or 8-hydroxyquinoline; the resulting vanadium-organic complexes were sorbed on to a C18 column at a flow rate of 5 mL min-1. The vanadium sorbed on the C18 columns was then stripped by use of nitric acid (2 mol L-1) and analysed by inductively coupled plasma-atomic emission spectroscopy, ICP-AES. This method was optimised and use of other chelating resins, such as chelamine, chelex-100, and immobilised 8-hydroxyquinoline and was compared by passing seawater samples directly over the resins. The experimental conditions (pH, acid used for elution, and contact time between the liquid sample and the resin) were optimised. The results were compared for all the resins used and were indicative of excellent and coherent reproducibility. |